{"product_id":"1000v-insulated-duncan-style-meter-bypass-jumper-clamp","title":"1000V Insulated Duncan-Style Meter Bypass Jumper Clamp ASTM F1505 | IEC 60900","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eEngineered specifically for electrical utility professionals, the 1000V Insulated Duncan-style Meter Bypass Jumper Clamp is designed to establish a temporary electrical bypass on compatible older Duncan-style meter bases, allowing electrical meter removal, replacement, inspection and servicing without interrupting power to the customer.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFeaturing copper contact plates and a spring-loaded clamping mechanism, this specialized utility tool provides a secure mechanical connection to compatible meter terminal blocks. The opposing copper contact plates provide a conductive path for temporary electrical bypass applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe insulated shaft and clamp assembly provide protection against accidental contact with energized components, while the large, ribbed handle offers a comfortable, controlled grip during operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for professional utility field service, this specialized jumper clamp is particularly valuable when maintaining legacy electrical metering infrastructure where modern integrated bypass mechanisms may not be available.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eFeatures and Benefits\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e1000V Insulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to provide electrical protection during authorized utility service operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eDuncan-style Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Specifically designed for compatible legacy Duncan-style electrical meter bases.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eService Continuity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Facilitates temporary meter bypass to help prevent customer power interruptions during meter replacement and servicing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCopper Contact Plates:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provide conductive contact surfaces for electrical bypass applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSpring-Loaded Clamping Mechanism:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides controlled engagement with compatible meter terminal blocks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eInsulated Clamp Assembly:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Helps protect against accidental contact with surrounding energized components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eErgonomic Ribbed Handle:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides a comfortable grip and enhanced handling control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eMade in the USA.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDimension\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS303834CL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Length\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9-1\/8\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Clamping Gap\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9\/16\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCopper Contact Plate Width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.40\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOverall Insulated Clamp Width\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.59\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHandle Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1-1\/4\"\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContact Plate Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCopper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Voltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectric utility meter servicing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical meter replacement and removal\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTemporary electrical meter bypass\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLegacy Duncan-style meter base maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUtility field service operations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCustomer outage prevention during scheduled meter servicing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eProfessional Use Only:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Intended for qualified and authorized electrical utility personnel. Verify meter base compatibility and applicable electrical load limits before use. Always follow established utility procedures, electrical safety requirements, and appropriate PPE requirements. Intended for temporary bypass applications only.\u003c\/span\u003e\u003c\/p\u003e","brand":"1000vTools, LLC","offers":[{"title":"Default Title","offer_id":46703331311751,"sku":null,"price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0690\/6321\/3191\/files\/bypass_jumper.png?v=1795549294","url":"https:\/\/sip1000vtools.com\/es\/products\/1000v-insulated-duncan-style-meter-bypass-jumper-clamp","provider":"1000VTOOLS, LLC","version":"1.0","type":"link"}